Home / Home Care
Masimo is committed to helping hospitals transition patient care to home settings. With easy-to-use, hospital-grade monitoring solutions for use in the home, clinicians can provide high quality data and reliable continuous monitoring for patients requiring remote care.
Masimo's breakthrough Signal Extraction Technology® (SET®)—available for use in the home—overcomes the limitations of conventional pulse oximetry with the ability to measure through motion and low perfusion. Multiple studies have demonstrated that Masimo SET® outperforms conventional pulse oximetry technologies.1 In one study comparing the ability of three pulse oximetry technologies to detect hypoxic events, Masimo SET® pulse oximetry demonstrated the highest sensitivity and specificity during induced conditions of motion and low perfusion.2
Masimo SET® had 3% missed true alarms and 5% false alarms versus 43% and 28%, respectively, using competitor technology.2
Results shown are calculated by combining sensitivity and specificity outcomes of machine-generated and volunteer-generated motion.
At Masimo, innovation never stops. After these studies were published, Masimo achieved significant accuracy specification improvements for RD SET® sensors, improving from 3% ARMS to 1.5% ARMS* in conditions of motion.
Masimo supplies a range of advanced home care solutions that help ensure you can monitor with confidence from a distance, including:
Rad-97® is a compact, versatile Pulse CO-Oximetry platform featuring Masimo SET® pulse oximetry, optional integrated noninvasive blood pressure, and a responsive, intuitive multi-touch display that is easy to use for clinicians and non-clinicians alike. Home Mode on Rad-97 provides home users access only to relevant settings and messages, while hiding others and locking alarm settings, minimising the chances of inadvertent interference. Rad-97 also facilitates advanced connectivity with local hospital electronic medical records (EMRs), enabling the automatic transmission of patient data.
TNI softFlow® 50 delivers respiratory support through a soft nasal cannula for spontaneously breathing adult patients.
Oxygen
Saturation
Pulse Rate
Perfusion Index
Pleth Variability Index
Continuous Body Temperature
References:
Masimo. Clinical Evidence. https://www.masimo.com/evidence/featured-studies/feature/.
Shah N. et al. J Clin Anesth. 2012 Aug;24(5):385-91.
Hasani A et al. Chron Respir Dis. 2008;5(2):81-86.
Roca O et al. Respir Care. 2010;55(4):408-413.
*ARMS accuracy is a statistical calculation of the difference between device measurements and reference measurements. Approximately two-thirds of the device measurements fell within +/- ARMS of the reference measurements in a controlled study.
For professional use. See instructions for use for full prescribing information, including indications, contraindications, warnings, and precautions.